Supported Devices
MediCollector supports communication with the medical devices listed below. Keep in mind that manufacturers are constantly changing their lineup of devices. If you don't see your device below, it might still be compatible, or we could add it for a fee. Contact us for assistance.
In order to simplify your cabling needs, MediCollector sells "cable packs" for each device. Each cable pack contains instructions and cables for your specific device. Click on the relevant cable pack for detailed information and requirements for each device.
Direct connections: To connect your device directly to your computer, purchase a "Direct Cable Pack" (serial port required). If your computer doesn't have a serial port, you should also purchase a USB-to-Serial adapter. All our software products support direct cable connections.
Network connections: To collect data across a network, purchase one "Network Cable Pack" for each device. No additional USB-to-Serial adapter is needed. Network connections are only allowed in our MediCollector CENTRAL product.
In order to simplify your cabling needs, MediCollector sells "cable packs" for each device. Each cable pack contains instructions and cables for your specific device. Click on the relevant cable pack for detailed information and requirements for each device.
Direct connections: To connect your device directly to your computer, purchase a "Direct Cable Pack" (serial port required). If your computer doesn't have a serial port, you should also purchase a USB-to-Serial adapter. All our software products support direct cable connections.
Network connections: To collect data across a network, purchase one "Network Cable Pack" for each device. No additional USB-to-Serial adapter is needed. Network connections are only allowed in our MediCollector CENTRAL product.
Vendor |
Series |
Model Numbers |
Direct Cable Pack |
Network Cable Pack |
Device Driver |
Value |
Philips |
Intellivue |
MP5 MP20 - MP90 MX400-MX850 w/standard interface card MX400-MX550 w/advanced interface card |
Philips Intellivue & Avalon Series |
The following Intellivue models are NOT supported due to the lack of a serial port on the device: MP2, X2, X3, MX40 and MX100 |
||
Philips |
Avalon |
FM20 - FM50 |
Philips Intellivue & Avalon Series |
Avalon devices require SW REV J.3 or newer |
||
GE |
CARESCAPE |
B850 B650 B450 Canvas 1000 Canvas Smart Display |
GE S/5 Series |
|||
GE |
PROCARE |
B20 B40 B105 B125 |
GE S/5 Series |
|||
GE |
PROCARE |
B30 |
GE S/5 Series |
|||
GE |
S/5 Monitors S/5 Light Monitors |
S-00A01/02/05/06 L-00A03/04/07/08 S-00C01/02/03/04 L-ANE01(A) - L-ANE07(A) L-ICU01(A) - L-ICU07(A) L-CANE02(A) - L-CANE06(A) L-CICU02(A) - L-CICU06(A) L-FICU03(A) - L-FICU05L S/5 Light Monitors have numerous part numbers which are all supported |
GE S/5 Series |
Datex-Ohmeda is a division of GE, so the names GE and Datex-Ohmeda are interchangeable. |
||
GE |
Cardiocap 5 |
S-XANE99/01 S-XCCA99/01 S-XANE04SL |
GE S/5 Series |
|||
GE |
CS/3 Critical Care Monitor CS/3 Compact Monitor |
S-ICU97/98/99(A) |
GE S/5 Series |
|||
GE |
AS/3 Anesthesia Monitor AS/3 Compact Monitor |
S-STD95/96 S-ARK95/96/97/98 S-ANE97/98/99(A) L-ARK99(A) |
GE S/5 Series |
|||
GE Marquette |
Solar |
Solar 8000M Solar 8000i Solar 9500 |
GE Solar/Dash/Unity |
Only acquires numerics at 0.5 Hz (1 datapoint every 2 seconds). No waveforms, such as ECG and RESP. |
||
GE Marquette |
Dash |
Dash 2000/3000/4000/5000 Dash Port Docking Station Dash Port 2 Docking Station |
GE Solar/Dash/Unity |
Only acquires numerics at 0.5 Hz (1 datapoint every 2 seconds). No waveforms, such as ECG and RESP. |
||
GE |
Unity |
Unity Network Interface Device Unity ID |
GE Solar/Dash/Unity |
Only acquires numerics at 0.5 Hz (1 datapoint every 2 seconds). No waveforms, such as ECG and RESP. |
||
Draeger |
Infinity Acute Care System (IACS) |
Infinity Acute Care System (IACS) ... also called "Medical Cockpit" |
Draeger Infinity Series |
Draeger devices only export numerics at 1 Hz (1 datapoint every second). No waveforms such as ECG & RESP. |
||
Draeger |
Infinity |
Infinity Delta, Delta XL, Vista XL, Gamma X XL or the Siemens SC9000, SC9000XL, SC7000 Infinity Gamma, Gamma XL, Kappa, Vista or the Siemens SC5000, SC600X, SC8000 |
Draeger Infinity Series |
Draeger devices only export numerics at 1 Hz (1 datapoint every second). No waveforms such as ECG and RESP. |